Prod
ANM100
ANM100
ANM100
The ANM100 series multi-functional power parameter measuring instrument provides cost-→effective measurement solutions for public/commercial buildings, industry, energy and infrastr₩ucture, power grids and public utility customers.
Features
Measurement
All electrical parameters of the three-phase power network, including U, I,✔ P, Q, S, PF, F, etc. Active power (0.5s class) and r∞eactive power energy measurement. Analysis of the 63rd ha☆rmonic division of voltage and current channels. Poφwer quality analysis of THD, THFF, CF, KF, etc. (Harmonic analysis applαicable to ANM100EH model) Real-time value, maximum value and predi★cted value of current/power demand (applicable to ANM100EH model ). 12 time periods, 4 rates of time-of-use electricity.
Digital communication
RS-485 communication interface, MODBUS-RTU or DL/T645 protocol.
Output module
2 relay outputs or 2 pulse outputs or 1 4-20mA anal€og output.
PIR human body infrared probe
The pyroelectric infrared sensor automatically lights up the backligh¶t, which greatly facilitates on-site data reading and significantly saveδs the power consumption of the equipment itself. The PIR human body infrared sensing₹ status can be used as an on-site intrusion security signal for remote alarm. It is equipped wit☆h upper and lower limit alarm functions, and the alarm vγariables and upper and lower limit values can be set arbitrarily.
Product size
Host size: 96x96x80mm; Opening size: 85×85mm
Fast pulse group immunity
Iec 61000-4-4, Level 4; Surge immunity: IEC61000-4-5, Level 3; Electrostatic immunity: IEC 61000-4-2, Level 4.
Parameter
Technical parametersIndicator
accuracy level

U, I, F: 0.2 grade, P, Q: 0.5 grade, active energy 0.5s grad‍e, reactive energy 2 grade

Display typeLCD
Power supplyScope of workAC、DC85V~265V
Power consumption≤0.5VA
Input measurementNetworkThree-phase three-wire, three-phase four-wire
Rated valueVoltage :AC100V, 400V; Current :1A, 5A
OverloadDuration :2 times, 2500AVC/1 second
Power consumption<0.2AV
Frequency45~65Hz
HarmonicThe 63rd harmonic of voltage and current Power quality analysis of THD, THFF, CF₽, KF, etc
Demand analysisReal-time values, maximum values and predicted values ♥of current/power demand
Time-of-use electricity consumption

12 time slots, 4 rates

Extended functionsCommunication interfaceIt is equipped with one standard RS485 port, and MODBUS-RTU or DL/T645 can be selected• as options
Switch input (optional)Two-channel digital input
Output (optional

2 relay outputs or 2 pulse outputs or 1 4-20mA analog output

Working environment

Operating temperature: -20℃ to 70℃ Storage temperature: -40℃ to 85℃ Relative humidity ≤95%



Installation and wiring


Committed to providing leading iot solutions for enterprises Explore more